SS7 Programmers Manual for SPCI2, SPCI4 and CPM8 Issue 2 Page 55
5.3.3 LIU Read Configuration Request
Synopsis:
Message sent by the application to read back the current LIU configuration from
the board.
Message Format:
MESSAGE HEADER
FIELD NAME MEANING
type LIU_MSG_R_CONFIG (0x5e37)
id
liu_id (0 .. 7)
src
Sending Module ID
dst MVD_TASK_ID (0x10)
rsp_req
used to request a confirmation
hclass
0
status
0
err_info
0
len
40
PARAMETER AREA
OFFSET SIZE NAME
0 40 Parameter area formatted as for as the
LIU_MSG_CONFIG message. The user
should set the fields to zero and the module
will write the current configuration parameters
in the confirmation message.
Description:
This message is sent to the board to read back the current operating
configuration of the Line Interface Unit.
The user should always request a confirmation message. This will indicate
success by a status of 0 and will contain the current configuration parameters in
the parameter area of the message.