Section 7 Management Interface
114
7.2 Circuit Group Supervision Control Request
This message is issued by system management to initiate a circuit group
supervision control function. The functions supported are RESET, BLOCK
UNBLOCK and QUERY. The command operates on specified circuits within the
specified circuit group.
Message Header
structure MSG
type ISP_MSG_CGSC_REQ (0x7703)
id gid
src Originating module ID
dst ISUP module ID
rsp_req Sending layer's bit set if confirmation required
hclass 0x00
status 0x00
err_info 0x00
len 6
Parameter Area
offset 0, size 1 ptype Management primitive type.
offset 1, size 1 reserved reserved - must be set to zero
parameters
offset 2, size 4: cic_mask Bits set to indicate affected circuits in group.
ISUP Response
method By returning the message to the sender
type 0x3703
status SUCCESS
ISP_BAD_ID
ISP_BAD_PARAM
Parameters
gid
The group identifier for the Circuit Group.
ptype
The type of management primitive taken from the following table:
Value Name Function
0 Reset Reset circuit(s)
1 Stop Reset Abort reset operation
Note: The circuits specified in this message must be identical to
those in the Reset Request message.
2 M-Block Maintenance block circuit(s)