35
6.5.11 Facility Response
This message is used by the application to accept or reject a previously
requested user to user supplementary service 3 during the active (speech)
stage of a call.
Accepted
Message type
FAA (Facility Accepted Message)
Mandatory parameters
Facility indicator
Optional parameters
Call reference
User to user indicators
The following optional parameters are supported in ITU-T mode only:
Connection request
Parameter compatibility information
Rejected
Message type
FRJ (Facility Rejected Message)
Mandatory parameters
Facility indicator
Cause indicators
Optional parameters
Call reference
The following optional parameters are supported in ITU-T mode only:
User to user indicators
The following optional parameters are supported in ANSI mode only:
Called party number
Calling party number