Welltech Dialogic SS7 Protocols ISUP Manual de usuario Pagina 85

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 203
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 84
Dialogic
®
SS7 Protocols ISUP Programmer's Manual Issue 15
85
Value Length
Parameter Name
Hex Dec
Definition/Reference
Min Max
Notes
User service information
prime
0x30 48 Q.763 Section 3.58 2 11 1
User-to-user indicators 0x2a 42 Q.763 Section 3.53 1 1 -
User-to-user information 0x20 32 Q.763 Section 3.61 1 129 1
User teleservice
information
0x34 52 Q.763 Section 3.59 2 3 1
Notes
The ISUP module transports this parameter transparently without
verifying its format.
The length of this parameter depends on the length of a point code.
This parameter is generated within the ISUP module and is not passed
across the user interface.
This parameter may be repeated. Refer to Appendix E for further
information.
The minimum length of this parameter may differ depending on the ISUP
variant used:
Minimum Parameter Length
Parameter Name
ITU ANSI
Called party number 2 1
Originating line information - 1
Signalilng point code 2 3
Figure 1. Notation used for Parameter Specifications
The notation used for the parameter specifications is shown below:
MSB 7 6 5 4 3 2 LSB
Parameter name and value
Parameter length (in octets)
1 First octet of parameter
2
:
n Final octet of parameter
Vista de pagina 84
1 2 ... 80 81 82 83 84 85 86 87 88 89 90 ... 202 203

Comentarios a estos manuales

Sin comentarios